EMI EMC Testing Labs

Electrical Fast Transient Burst (EFT)

Standards Covered

IEC/EN 61000-4-4
IEC/EN 60730-1 Cl. ZD.6
IEC/EN 60730-2-7 Cl. 26
IEC/EN 60688 ed.3 Cl.6.22
IEC 61000-6-2 Cl.8 Table-2 Table-3,Table-4
IEC/EN 61326 – 1 - Cl.6.2,Table-1, Table-2,Table-3
IEC/EN 61000-6-1 Cl.8 Table-2 Table-3,Table-4
CISPR 24 Cl. 4.2.2, BS EN 55024 Cl. 4.2.2
CISPR 14-2, EN 55014-2, IS14700(part4/Sec4)

Equipment

Electrical fast transient Burst Generator
Make: EM test
Model :EFT 500N5.1

Specification

Voltage :0.2 kV to 5.5 kV
CDN: 3X690 V AC L-L, 32A
1000 V DC , 32 A
Coupling Clamp for Data line

Immunity to Electrostatic Discharges (ESD)

Standards Covered

IEC/EN 62052-11 Cl. 7.5.2
IEC/EN 62053-21 Cl. 8.2
IEC/EN 62053-22 Cl.8.2
IEC/EN 62053-23 Cl. 8.2
IEC/EN 61000-4-2
IEC/EN 61000-6-1 Cl.8 Table-1
IEC/EN 61000-6-2 Cl.8 Table-1
IEC/EN 60730-1 Cl. ZD.7.2
IEC/EN 60730-2-7 Cl.26
IEC/EN 60688 ed.3 Cl.6.22
EN 55024 Cl.4.2.1
EN 55014-2
CISPR 24 Cl.4.2.1
CISPR 14-2
IS 13779 Cl. 12.9.2
IS 14697 Cl. 12.8.2
IS 14700(part4/Sec2)

Equipment

Electrostatic Discharge Simulator with Gun
Make: EM test
Model :NX 30

Specification

Voltage :0.2 kV to 30 kV
Contact and Air Discharge

Surge Immunity Test

Standards Covered

IEC/EN 62052-11 Cl. 7.5.2
IEC/EN 62053-21 Cl. 8.2
IEC/EN 62053-22 Cl.8.2
IEC/EN 62053-23 Cl. 8.2
IEC/EN 61000-4-5
IEC/EN 60688 ed.3 Cl.6.22
IEC/EN 61000-6-1 Cl.8 Table-1
IEC/EN 61000-6-2 Cl.8 Table-1
IEC/EN 61326 – 1Cl.6.2 Table-1, Table-2,Table-3
IEC/EN 60730-1 Cl. ZD.7.2, IEC/EN 60730-2-7 Cl.26
CISPR 14-2
CISPR24 Cl.4.2.1
EN 55014-2
EN 55024 Cl.4.2.1
IS14700(part4/Sec5)

Equipment

Ultra Compact Simulator
Make: EM test
Model UCS 500 N7
CDN: CNI503B7

Specification

Voltage : 0.25 kV to 7kV
CDN: 3X690 V AC , 32A 1000 V DC , 32 A

Test of Immunity to Conducted Disturbances, Induced by Radio Frequency Fields (CS)

Standards Covered

IEC/EN 61000-4-6
IEC/EN 60730-1 Cl. ZD.7.2
IEC/EN 60730-2-7 Cl.26
IEC/EN 60688 ed.3 Cl.6.22
IEC/EN 61000-6-1 Cl.8 Table-1
IEC/EN 61000-6-2 Cl.8 Table-1
IEC/EN 61326 – 1Cl.6.2 Table-1, Table-2,Table-3
CISPR 24 Cl.4.2.1
CISPR 14-2
EN 55024 Cl.4.2.1
EN 55014-2

Equipment

Model CWS500N1.4
Make: EM test
CDN: CDN M232, CDN M532,CDN M016
EM Clamp and Attenuation Clamp for Data Line

Specification

Voltage :Up to 10 Vrms
CDN: 520 V AC L-L, 32 A 400V DC , 32A

Immunity to Electromagnetic HF Field using Anechoic Chamber

Standards Covered

IEC/EN 61000-4-3
IEC/EN 60730-1 Cl.ZD.7
IEC/EN 60730-2-7 Cl.26
IEC/EN 60688 ed.3 Cl.6.22
IEC/EN 61000-6-1 Cl.8 Table-1
IEC/EN 61000-6-2 Cl.8 Table-1
IEC/EN 61000-6-1
IEC/EN 61000-6-2 Cl.8 Table-1
IEC/EN 61326 -1Cl.6.2 Table-1, Table-2,Table-3
EN 55024 Cl. 4.2.3.2
EN 55014-2
CISPR24 Cl.4.2.3.2
CISPR 14-2
IS14700 (part4/Sec3)

Semi Anecohic Chamber

Make : Frankonia
Model : SAC 3 L Plus
Freq : 26 MHz to 18 GHz

Instrumentation

Signal generator
Make: Rohde & Schwarz
Model: SMB100A , 9 kHz to 6 GHz.

Power Amplifier
Make: Rohde & Schwarz
Model: BBA 150/BC250/D11E60 : 80 MHz to 6 GHz

Specification

Amplitude: 10 V/m @ 3 m Distance
EUT Voltage AC: 0-415 L-L AC
EUT Voltage DC: 0-1000 V DC
EUT Current: 32 A max
EUT Size: 1.5m X 1.5 m

Radio interference Measurement - Conducted Emission (CE)

Standards Covered

IEC/EN 62052-11Cl. 7.5.8
IEC/EN 62053-21 Cl. 8.2
IEC/EN 62053-22Cl. 8.2
IEC/EN 62053-23 Cl. 8.2
IEC/EN 60688 ed.3 Cl. 6.22
IEC/EN 60730-1, Cl.H.23.1.2
IEC/EN 60730-2-7 Cl.23
IEC/EN 61000-6-3 Table-1
IEC/EN 61000-6-4 Table-1
IEC/EN 61326-1 Cl.7
IEC/EN 61000-3-2
IEC/EN 61000-3-3
CISPR 11
CISPR 22 Cl.5
CISPR 32
EN 55032
EN 55022
IS 13779 Cl. 12.9.5
IS 14697 Cl. 12.8.5

Equipment

EMI Receiver
Make: Rohde & Schwarz
Model: ESR 7 LISN
Make: Rohde & Schwarz
Model: ENV 432
Current Probe for data Lines
Make: Rohde & Schwarz
Model: EZ -17

Specification

Frequency : 9 KHz to 30 MHz
EUT Voltage AC: 0-415 L-L AC
EUT Voltage DC: 0-350 V DC
EUT Current : 32 A max
Current Probe: 20 Hz to 100 MHz

Radio interference Measurements- Radiated Emission (RE)

Standards Covered

IEC/EN 62052-11Cl. 7.5.8
IEC/EN 62053-21 Cl. 8.2
IEC/EN 62053-22Cl. 8.2
IEC/EN 62053-23 Cl. 8.2
IEC/EN 60688 ed.3 Cl. 6.22
IEC/EN 60730-1 Cl.H.23.1.2
IEC/EN 60730-2-7 Cl.23
IEC/EN 61000-6-3 Table-1
IEC/EN 61000-6-4 Table-1
IEC/EN 61326-1 Cl.7
IEC/EN 61000-3-2
IEC/EN 61000-3-3
CISPR 11
CISPR 22 Cl.5
CISPR 32
EN 55032
EN 55022
IS 13779 Cl. 12.9.5
IS 14697 Cl. 12.8.5

Semi Anecohic Chamber

Make : Frankonia
Model : SAC 3 L Plus
Freq : 26 MHz to 18 GHz

Equipments

EMI Receiver
Make: Rohde & Schwarz
Model:: ESR 7
Trilog Broad band Antenna
Make: Schwarzbeck MESS
Model: VULB9162

Specification

Frequency : 9 KHz to 6 GHz
EUT Voltage AC :0-415 L-L AC
EUT Voltage DC: 0-1000 V DC
EUT Current : 32 A max

Power Frequency Magnetic Field (PFMF)

Standards Covered

IEC/EN 61000-6-1 Cl.8 Table-1
IEC/EN 61000-6-2 Cl.8 Table-1
IEC/EN 61000-4-8
IEC/EN 61326-1 Cl.6.2 Table-1, Table-2
IEC/EN 60730-1 Cl.ZD.9
IEC/EN 60730-2-7 Cl. 26
IEC/EN 60688 ed.3 Cl.6.22
CISPR 24 Cl.4.2.4
EN 55024 Cl. 4.2.4

Equipment

Magnetic Field generator
Make: PMM/NARDA
Model : PMM 1008-1
1m Square Current Coil
Make: PMM/NARDA
Model : PMM 1008-2

Specification

Current :170 A (Continuous Mode)
1200A ( Short Mode)
EUT Size: 0.6m X 0.6m X 0.5m (height)

Voltage Dips & Interruptions (VDI)

Standards Covered

IEC/EN 61000-4-11
IEC/EN 60601-1-2 Ed3.0
IEC/EN 60730-1 Cl. ZD.10
IEC/EN 60730-2-7 Cl.26
IEC/EN 60688 Cl. 6.23
IEC/EN 61000-6-1 Cl.8 Table-4
IEC/EN 61000-6-2 Cl.8 Table-4
IEC/EN 61000-6-1 Cl.8 Table-4
IEC/EN 61000-6-2 Cl.8 Table-4
IEC/EN 61326-1: Cl.6.2 Table-1, Table-2,Table-3
IEC/EN 61326-1 Cl.6.2 Table-1, Table-2,Table-3
EN 55014 -2 Cl. 5.7
EN 55014-2
EN 55024 Cl.4.2.6
CISPR 14-2
CISPR 24 Cl.4.2.6
CISPR 14-2 Ed 1.2, Cl. 5.7
IS 12784 (Part 1) Cl.8.6

Equipment

VDI Generator
Make: : EM test
Model : PFS503N32
Variac : MV3P4032DS

Specification

Dips : 0 to 100%
Voltage : 3 X 400 V L-L
Current : 3 X32 A